国产无遮挡又爽又黄大胸免费丨蕾丝av无码专区在线观看丨成人午夜亚洲精品无码网站丨亚洲精品综合欧美一区二区三区丨欧美熟妇的性裸交

全國服務咨詢熱線:

15618996225

當前位置:首頁  >  產品中心  >  太赫茲  >  太赫茲功率計  >  Mm-Wave power meter高靈敏度毫米波功率計

高靈敏度毫米波功率計

簡要描述:高靈敏度毫米波功率計Features
0.01-220 GHz operating frequency
High sensitivity
Up to 55 dB dynamic range (0.1uW-30mW)
Small measuring time (< 1 sec)
RS-232, GPIB interface
SCPI protocol

  • 產品型號:Mm-Wave power meter
  • 更新時間:2025-03-12
  • 訪  問  量:1053

產品簡介

品牌其他品牌產地類別進口
應用領域農林牧漁,電子/電池,汽車及零部件,電氣

詳細介紹

 

高靈敏度毫米波功率計Features  
  • 0.01-220 GHz operating frequency

  • High sensitivity

  • Up to 55 dB dynamic range (0.1uW-30mW)

  • Small measuring time (< 1 sec)

  • RS-232, GPIB interface

  • SCPI protocol

高靈敏度毫米波功率計Applications  
  • Recommended for use by Rohde & Schwarz

  • Measurements of power level of mm-wave signal

  • Test equipment

Description

The DPM-xx is a single-channel average power meter for RF to millimeter wave frequencies that measures absolute power from 10 MHz to 220 GHz.

DPM-xx Power Meters display measured power in milliWatts, microWatts or dBm, and also display the user-entered signal frequency in GHz. Easy operation is ensured with automatic zeroing, automatic sensor recognition and a calculation factor table stored in the memory of each power sensor.

Their compact size, precise accuracy, reliability and inexpensive pricing make our DPM-xx Power Meters attractive assets for design engineering, equipment manufacturing, field engineering and research.

ELVA-1’s ZBD-series Zero-Biased Detectors are used as the power sensors for our DPM Power Meters.To cover the range from 10MHz to 220GHz band, we offer one coaxial (10 MHz-26.5 GHz) and 9 waveguide power sensors (26.5-220 GHz in waveguide bands), sold separay.

Based on Schottky Barrier Diode technology, our ZBD power sensors provide high sensitivity, fast measurement speed and quick response to changes of input power. To extend the dynamic range of diode power sensors above their square law region, a correction factor is used. The amplitude and frequency curves for each individually-calibrated power sensor are stored in the sensor’s EEPROM. When a sensor is connected to a DPM control/display unit, the control/display unit automatically recognizes that sensor’s characteristics. The typical curves for amplitude and frequency transfer characteristics at W-band are shown on the reverse.

Measured average power is displayed on a 2-line LCD screen, at a measurement rate of 2 times per second or faster. For power measurements below 10-100mW (depending on frequency band), each sensor is supplied with a full-band isolator. For power measurements above those levels (as high as 300mW-1Watt), optional directional couplers are available.

Every DPM-xx is equipped with an RS-232 port for control and measurement data exchange with a PC. An internal GPIB interface board is available as an added option. On special request we can also provide a dual channel power meter of DPMD-XX series with two independent measurement channels.

Since the control/display unit and power sensors are sold separay, customers only need one DPM control/display unit to interface with all 10 of our sensors. To obtain power measurements over a multi-waveguide frequency range, order one DPM control/display unit and several adjacent-band sensors.  Because the standard ELVA-1 DPM control/display unit is a single-channel meter, only one power sensor can be used at one time.

 

DPM-XX Key Features and Specifications

- Display readings: milliWatts, microWatts or dBm

- Maximum measuring rate: up to 50 times per second, default 2 times per second (set at factory)

- Frequency Range: 10 MHz to 220 GHz

- Min. measured Power: 0.1 microWatt (depending on frequency band)

- Dynamic Measurement Range: 55dB max. (depending on frequency band)

- Frequency step: 10 MHz

- SCPI or ELVA’s command protocol

- RS-232, GPIB interface

- Calibration accuracy ±0.04 dB (log) or ±1%

- Power Sensor Calibration: Individually calibrated, with amplitude and frequency curves in flash memory

- If a valid signal frequency is not entered before measuring power, maximum measurement error will be ±1.5dB for Ka, Q, U, V bands, ±2.0dB for E, W bands, and ±2.5dB for F, D bands, based on calibration curve flatness.

Model Number DPM-C DPM -28 DPM -22 DPM -19 DPM -15 DPM -12 DPM -10 DPM -08 DPM -06 DPM -05
Frequency Band Ka Q U V E W F D G
Frequency Range, GHz 0.01-26.5 14757 33-50 40-60 50-75 60-90 75-110 90-140 110-170 140-220
Input Waveguide/Impedance 50 Ohm, Coaxial WR-28 WR-22 WR-19 WR-15 WR-12 WR-10 WR-08 WR-06 WR-05
Wavequide Flange/Connector SMA, male UG-599/U UG-383/U UG-383/U-M UG-385/U UG-387/U UG-387/U-M UG-387/U-M UG-387/U-M UG-387/U-M
Dynamic Range, dB (max) 50 55 55 55 55 55 55 55 50 40
Min Measured Power Level, dBm -33 -43 -43 -43 -43 -43 -40 -40 -35 -25
Measurement Rate (default), times per sec 2 2 2 2 2 2 2 2 2 2
VSWR (power sensor) 1.2:1 1.3:1 1.3:1 1.3:1 1.3:1 1.4:1 1.4:1 1.4:1 1.4:1 1.4:1

Available operating power options: 220 VAC, 110/100 VAC, or battery power (for portable version).

 

產品咨詢

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7

全國統一服務電話

021-62209657

電子郵箱:sales@eachwave.com

公司地址:上海市閔行區劍川路955號707-709室

業務咨詢微信

主站蜘蛛池模板: 亚洲国产长腿丝袜av天堂| 久久午夜电影网| 四虎国产精品永久地址49| 亚洲香蕉网久久综合影视| 被灌满精子的少妇视频| 亚洲丶国产丶欧美一区二区三区| 中文无码不卡的岛国片| 青青草国产免费久久久| 日本高清色本在线www| 日韩免费特黄一二三区| 天堂中文在线www天堂在线| 亚洲日韩av无码中文字幕美国| b站永久免费看片大全| 人人妻人人澡人人爽人人dvd| 久久99国产综合精品| 久久久亚洲欧洲日产国码是av| 欲色影视天天一区二区色香欲| 动漫精品专区一区二区三区| 欧美激情肉欲高潮视频| 亚洲国产精品无码久久sm| 国产+成+人+亚洲欧洲自线| 2020精品国产午夜福利在线观看| 天堂在线www天堂在线| 精品无码中文字幕在线| 伊人久久大香线蕉av网站| 亚洲国产精品久久久久婷婷软件| 亚洲中文字幕无码一区二区三区| 欧美黑人粗暴多交高潮水最多 | 最新国产亚洲人成无码网站| 77777亚洲午夜久久多喷 | 性无码专区无码| 白嫩日本少妇做爰| 亚洲人成电影在线观看青青| 国产成人精品高清在线观看99| 国产人成视频在线观看| 99久久精品午夜一区二区| 亚洲国产欧美国产第一区| 日日天干夜夜狠狠爱| 亚洲国产精品无码中文字2022| 无遮挡又爽又刺激的视频| 吃奶摸下高潮60分钟免费视频 |